AQUA-K9

Acoustic. Tracer gas.
One system.

Professional leak detection without being limited to one detection method.

Explore the AQUA-K9
Passa alle informazioni sul prodotto
1 su 16

AQUA-K9

Acoustic + Tracer Gas Leak Detection

AQUA-K9

AQUA-L7

Prezzo di listino $12,990 AUD
Prezzo di listino Prezzo di vendita $12,990 AUD
Vendita Esaurito
  • Free International Shipping
  • 5-Year Warranty
  • Lifetime Aqua Support

Product information

Everything you need to get familiar with the AQUA-K9.

The AQUA-K9 combines Acoustic Detection and Tracer Gas Detection in one professional field system. The AQUA-K9 is suitable for indoor, outdoor, shallow, deep-buried, and tracer gas leak detection.

This kit includes a range of specialist sensors, each designed for a different environment. From indoor floors and confined areas to outdoor surfaces, buried pipelines, and more difficult jobs requiring tracer gas, the AQUA-K9 gives the operator the flexibility to adapt to the conditions on site.

Leak sounds and sensor feedback are processed by the Control Unit and displayed on the screen in real time through waveform analysis and numerical values. At the same time, sound is transmitted to the headphones, allowing the operator to both hear and analyse the signal while comparing test points. This helps reduce guesswork, improves pinpointing accuracy, and minimises unnecessary digging.

For more difficult jobs where acoustic conditions may not be ideal, the AQUA-K9 also includes tracer gas detection capability, allowing escaping gas concentrations to be detected and used to further narrow down the leak location.

AQUA-K9 Features

  • Designed for indoor, outdoor, and tracer gas leak detection
  • Multi-sensor configuration for a wide range of surfaces and environments
  • Includes specialist sensors for shallow and deeper buried pipeline detection
  • Time-domain waveform visualisation
  • Real-time waveform visualisation and numerical feedback
  • Adjustable gain, volume, and frequency filtering
  • Up to 8 hours working time
  • Rechargeable battery system
  • 7-inch LCD
  • Suitable for municipal, industrial, residential, and commercial applications
  • Audio recording supported
  • Lifetime Aqua Support
  • Simple and easy-to-use interface
  • Robust and heavy-duty casing

Product Principle

The AQUA-K9 works by detecting the vibration and sound created when pressurised water escapes from a pipe. Using a range of specialist acoustic sensors, the unit captures leak signals through floors, walls, outdoor surfaces, soil, and other environments where a leak may be present.

These signals are then processed by the Control Unit, where they are shown visually through live waveforms and numerical values while also being transmitted to the headphones. This gives the operator both an audible and visual way to compare signal strength and identify the most likely leak location.

As the sensor moves closer to the leak, the signal generally becomes clearer and stronger, helping the operator narrow down the burst location more efficiently.

For more challenging jobs, the AQUA-K9 also features a Gas Sensor, which can detect escaping gas at the surface and provide an additional method of locating the leak when acoustic conditions are less favourable.

This combination of multiple sensor options and real-time signal analysis makes the AQUA-K9 a highly capable solution for professionals who need flexibility, accuracy, and confidence before breaking ground.

What’s Included

  • Medium Outdoor Floor Sensor
  • Large Outdoor Floor Sensor
  • Indoor Wall Sensor
  • Indoor Floor Sensor
  • Gas Sensor
  • Listening Rod / Probe Set
  • Control Unit
  • Headphones
  • Hand Controller
  • Protective Transport Case

Ideal For

  • Plumbing professionals
  • Leak detection specialists
  • Civil and municipal maintenance
  • Fire service and infrastructure applications
  • Industrial pipeline diagnostics
  • Residential and commercial leak detection

Introducing the AQUA-K9

Meet the AQUA-K9, our professional leak detection platform combining acoustic and tracer gas detection in one field-ready system. Discover the K9 equipment, detection modes and the versatility it brings to professional leak detection.

How to Use the AQUA-K9

Learn how to set up and operate the AQUA-K9, select the appropriate detection method and work with the system in the field. This guide walks through the key controls and functions for both acoustic and tracer gas leak detection.

Coming soon.

  • Medium Outdoor Floor SensorFor acoustic detection on outdoor hard and soft ground, supporting buried-pipeline applications at depths up to 3 m, depending on field conditions.
  • Large Outdoor Floor SensorDesigned for deeper outdoor acoustic detection on hard or soft ground, supporting buried-pipeline applications at depths up to 6 m, depending on field conditions.
  • Indoor Wall SensorCompact high-contact acoustic sensor for walls, fittings, narrow gaps and confined indoor areas where precise contact is required.
  • Indoor Floor SensorAcoustic contact sensor for general indoor and floor-surface leak detection where stable surface contact is required.
  • Gas SensorTracer Gas Detection for locating escaping gas from pressurised pipelines, with detection capability up to 8 m depending on field conditions.
  • Listening Rod / Probe SetExtends direct-contact acoustic testing to fittings, valves and ground applications using compatible probes and rods.
  • Control UnitCentral AQUA-K9 interface with a 7-inch LCD for live waveform analysis, numerical signal feedback, detection modes and recorded field data.
  • HeadphonesClosed-back monitoring headphones for listening to acoustic leak signals and comparing changes between test points.
  • Hand ControllerProvides sound collection plus convenient gain and volume adjustment while operating connected acoustic sensors.
  • Protective Transport CaseOrganised protective storage for the AQUA-K9 control unit, sensors, probes and accessories during transport and field work.

Two technologies.
One system.

Choose the detection method that suits the leak — without changing platforms.

Acoustic Detection

Acoustic Detection

Listen for the leak.

Use acoustic sensing to locate leak noise through the AQUA-K9 platform.

Tracer Gas Detection

Tracer Gas Detection

Find what sound cannot reveal.

Switch to tracer gas detection when acoustic conditions make pinpointing the leak difficult.

Built for professional leak detection.

A complete detection platform designed to give professionals more flexibility, clearer information and confidence in the field.

  • Precision you can see and hear

    Compare leak signals using live waveform analysis, numerical feedback and headphone audio.

  • Two detection methods

    Move between acoustic leak detection and tracer gas detection using the same AQUA-K9 platform.

  • Adjustable signal control

    Fine-tune gain and volume across 10 levels each, with frequency filtering for changing acoustic conditions.

  • Multi-sensor flexibility

    Configure the AQUA-K9 for indoor, outdoor and buried-pipeline work, with dedicated sensor options for different surfaces and detection depths.

  • Training & onboarding

    Practical guidance covering setup, sensor selection and AQUA-K9 detection workflows.

  • Built for the field

    Rugged equipment, organised accessories and protective transport for professional use.

Engineered for the field.

Professional capability in one integrated leak detection system. Detection depth varies by sensor and field conditions.

  • 2-in-1

    Acoustic + Tracer Gas

  • Up to 8 hours

    Working time

  • 7-inch LCD

    Display

  • 5 years

    Warranty

  • Lifetime

    Aqua support

  • Up to 8 m

    Tracer gas detection depth

One case.
Every tool.

Explore the control unit, sensors and accessories that make up the complete AQUA-K9 field kit.

One case.
Every tool.

COMPONENT

01 / 10

Medium Outdoor Floor Sensor

For acoustic detection on outdoor hard and soft ground, supporting buried-pipeline applications at depths up to 3 m, depending on field conditions.

COMPONENT

02 / 10

Large Outdoor Floor Sensor

Designed for deeper outdoor acoustic detection on hard or soft ground, supporting buried-pipeline applications at depths up to 6 m, depending on field conditions.

COMPONENT

03 / 10

Indoor Wall Sensor

Compact high-contact acoustic sensor for walls, fittings, narrow gaps and confined indoor areas where precise contact is required.

COMPONENT

04 / 10

Indoor Floor Sensor

Acoustic contact sensor for general indoor and floor-surface leak detection where stable surface contact is required.

COMPONENT

05 / 10

Gas Sensor

Tracer Gas Detection for locating escaping gas from pressurised pipelines, with detection capability up to 8 m depending on field conditions.

COMPONENT

06 / 10

Listening Rod / Probe Set

Extends direct-contact acoustic testing to fittings, valves and ground applications using compatible probes and rods.

COMPONENT

07 / 10

Control Unit

Central AQUA-K9 interface with a 7-inch LCD for live waveform analysis, numerical signal feedback, detection modes and recorded field data.

COMPONENT

08 / 10

Headphones

Closed-back monitoring headphones for listening to acoustic leak signals and comparing changes between test points.

COMPONENT

09 / 10

Hand Controller

Provides sound collection plus convenient gain and volume adjustment while operating connected acoustic sensors.

COMPONENT

10 / 10

Protective Transport Case

Organised protective storage for the AQUA-K9 control unit, sensors, probes and accessories during transport and field work.

For acoustic detection on outdoor hard and soft ground, supporting buried-pipeline applications at depths up to 3 m, depending on field conditions.

Designed for deeper outdoor acoustic detection on hard or soft ground, supporting buried-pipeline applications at depths up to 6 m, depending on field conditions.

Compact high-contact acoustic sensor for walls, fittings, narrow gaps and confined indoor areas where precise contact is required.

Acoustic contact sensor for general indoor and floor-surface leak detection where stable surface contact is required.

Tracer Gas Detection for locating escaping gas from pressurised pipelines, with detection capability up to 8 m depending on field conditions.

Extends direct-contact acoustic testing to fittings, valves and ground applications using compatible probes and rods.

Control Unit

Central AQUA-K9 interface with a 7-inch LCD for live waveform analysis, numerical signal feedback, detection modes and recorded field data.

Closed-back monitoring headphones for listening to acoustic leak signals and comparing changes between test points.

Provides sound collection plus convenient gain and volume adjustment while operating connected acoustic sensors.

Organised protective storage for the AQUA-K9 control unit, sensors, probes and accessories during transport and field work.

Technical specifications.

Key system, acoustic-processing and operating specifications for the AQUA-K9 platform.

Signal & analysis

Sampling rate
96 kHz
ADC resolution
24-bit
Gain adjustment
10 levels
Volume adjustment
10 levels
Signal display
Time-domain waveform visualisation
Comparison mode
Up to 16 comparative test points
Audio recording
Supported

Display & storage

Display
7-inch LCD
Display resolution
1024 × 600
Data storage
8 GB MicroSD
Recorded field data
Supported

Power & operating

Battery capacity
7000 mAh
Working time
Up to 8 hours
Charging input
5 V / 2 A
Charging time
Up to 5 hours
Operating temperature
−20°C to 50°C

Sensor depth capability

Medium Outdoor Floor Sensor
Up to 3 m
Large Outdoor Floor Sensor
Up to 6 m
Tracer Gas Detection
Up to 8 m

Detection depth varies by sensor, field conditions and application. Depth figures are sensor-specific and should not be interpreted as a universal AQUA-K9 detection depth.

Support that stays with you.

Professional equipment deserves professional support, from first setup through years of field use.

The AQUA-K9 is backed by a 5-Year Warranty for long-term confidence in your equipment investment.

Practical guidance is available to help operators understand system setup, sensor selection, acoustic detection and tracer gas workflows.

Access ongoing product guidance and technical support from Aqua throughout the life of your AQUA-K9 system.

Professional servicing and repair support is available should your AQUA-K9 equipment require inspection, maintenance or technical attention.

Common questions.

Yes. The AQUA-K9 combines acoustic leak detection and tracer gas detection within one professional platform, allowing the operator to select the method suited to the application.

The AQUA-K9 provides up to 8 hours of working time, depending on operating conditions and use.

Detection depth varies by sensor and field conditions. Medium Outdoor Floor Sensor: up to 3 m. Large Outdoor Floor Sensor: up to 6 m. Tracer Gas Detection: up to 8 m. These are sensor-specific capabilities, not guaranteed or universal detection depths.

Yes. The AQUA-K9 supports different sensor configurations for indoor surfaces, walls, outdoor ground applications and buried pipelines.

Practical training and onboarding guidance are available to help operators understand AQUA-K9 setup, sensor selection and detection workflows.

The AQUA-K9 is backed by a 5-Year Warranty and Lifetime Aqua Support.

Ready to find the leak?

Choose the AQUA-K9 for professional acoustic and tracer gas leak detection in one field-ready system.

Buy the AQUA-K9 today
Questions before ordering?Contact us
  • Chevron
  • Downer
  • TMG
  • BULCS Holdings
  • Rous County Council
  • HIA